Hot Water Calorifier

Provides 24×7 hot water required by residents on Oil Platforms and Mother Ships.

Specifications

  • 1) Design temp

    85 Deg C, Operation – 55 deg C.

  • 2)Pressure

    Typically 6-7 bars

  • 3) Pressure Vessel

    SS316L

  • 4) Pumps 

    2 x 100% pump configuration

  • 5) Heater Elements

    NiCr element, SS316L tubing,  Indirect heating – replaceable element without draining, IP55 terminal box.

  • 6) Control System

    :  PLC Controlled – PID temperature control matching demand & heating  capacity with Power optimisation

  • 7) Safety

    Low level interlock , High temp water alarm & trip, high temp heater trip

     

  • 8)Certification

    DNV/ABS offshore rules as applicable & required by Project

  • 9)Certification

    Piping & Valves as per API/ANSI/DIN standard